Skip to main content

Sungrow DC 120/150/180kW

Isolated Air-Cooling Fast DC Charger Sungrow DC 120/150/180kW.

IDC180E.

Category:

Description

Sungrow IDC180E : Technical Specifications

 

DC Output Performance

  • Maximum Output Power: 180 kW (Configurable as 180 kW x 1 or 90 kW x 2).

  • DC Output Voltage Range: 200 Vdc – 920 Vdc (Wide adaptive voltage range).

  • Connectors: Dual CCS2 ports (Outlet 1: 250 A; Outlet 2: 250 A, with 380 A/400 A optional).

  • Output Cable Length: 5 m (7 m optional).

AC Input Specifications

  • Nominal Voltage: 3 / N / PE, 400 Vac (± 10%).

  • Nominal Frequency: 50 Hz / 60 Hz.

  • Power Factor: ≥ 0.99

  • Total Harmonic Distortion (THDi): < 5 % at full output power.

  • Standby Power Consumption: ≤ 48 W.

  • Efficiency: Max. efficiency up to 96.5%.

User Interface & Connectivity

  • Display: 10-inch color touchscreen (IK08 impact protection).

  • Authentication (Standard): RFID card / Plug & Play / Auto-charge.

  • Authentication (Optional): Plug & Charge / Debit or credit card (payment terminal).

  • Communication Protocols: OCPP 1.6J (Ready for 2.0.1).

  • Communication Interfaces: 4G / Ethernet / WLAN (Wi-Fi), Bluetooth.

  • Software Updates: Over-the-Air (OTA) via iEnergyCharge app.

  • Energy Metering: MID and Eichrecht compliant meters available as options.

Mechanical & Environmental Data

  • Dimensions (W x H x D): 930 mm x 1930 mm x 615 mm.

  • Weight: ≤ 500 kg (approx. 480 kg).

  • Installation Method: Floor-mounted.

  • Enclosure Rating: IP65 (complete resistance against dust and water ingress).

  • Anti-Corrosion Degree: C5 (very high protection).

  • Mechanical Impact Protection: IK10 (enclosure).

  • Operating Temperature Range: -35°C to +55°C.

  • Cooling Method: Isolated air-cooling (Intelligent forced air circulation).

  • Noise Level: ≤ 65 dB ( A ) at 1 m distance / 25 °C , at full output power

General Features & Compliance

  • Lifespan: Designed for over 10 years of service life.

  • Maintenance: Maintenance-free, with no need to replace the dust filter mat.

  • Certifications: CE, CB, UKCA, LVD, REACH, RED, RoHS, and various IEC/EN standards.

  • Protection: Includes over/under voltage, over current, short circuit, leakage current, over temperature, and surge protection.