Skip to main content

Sungrow DC 30 kW

Isolated Air-Cooling Sungrow DC Charger 30 kW.

IDC30E.

Category:

Description

Sungrow IDC30E Technical Parameters

 

Charging Connector

  • Connector type: CCS2

  • EVSE-vehicle protocol: DIN SPEC 70121, ISO 15118 

  • Number of EV served: 1

  • Cable length: 5 m 

DC Output

  • DC output power: 30 kW 

  • DC output voltage: 200 Vdc – 1000 Vdc 

  • DC output current: 80 A 

AC Input

  • Grid voltage: 3/N/PE, 380 Vac/400 Vac (±10%) 

  • Nominal grid frequency: 50 Hz/60 Hz 

  • Grid frequency range: 45 Hz – 65 Hz 

  • Earthing system: TN-C, TN-S, TN-C-S, TT 

  • Rated input current: 46 A 

  • Max. Input current: 52 A 

  • Power factor: > 0.99 

  • Total harmonic distortion (THDI): < 5% at full output power 

  • Overvoltage category: III 

Efficiency

  • Max. efficiency: 96.5% 

Protection

  • Over/under voltage protection: Yes 

  • Over-current protection: Yes 

  • Short-circuit protection: Yes 

  • Over-temperature protection: Yes 

  • Surge protection: Yes 

  • Emergency stop: Yes, integrated 

User Interface

  • Display: 7-inch color touch screen 

  • Language: English (default); other languages available by firmware upgrade 

  • Authentication: RFID-card, Plug & Play, Auto-charge (default); Plug & Charge, Payment terminal (optional) 

  • Firmware update: Over-the-air (OTA) by EnergyCharge 

  • RFID system: ISO/IEC 14443 A/B, ISO/IEC 15693 

  • Energy metering: MID metering (CE compliant); Eichrecht/PTB compliant (optional) 

  • Communication interface: 4G, Ethernet, WLAN 

  • Communication protocol (charger-to-CSMS): OCPP 1.6 J; Ready for OCPP 2.0.1 

Mechanical Data

  • Dimensions (W*H*D): 500 mm * 800 mm * 288 mm 

  • Weight: 55 kg 

  • Installation method: Wall-mounting (default); Stand column, trolley (optional) 

  • Mechanical impact protection: IK10** (Note: The mechanical impact protection degree of HMI is IK08) 

Environmental Data

  • Degree of protection: IP65 

  • Anti-corrosion degree: C5 

  • Operating ambient temperature range: -35 °C to 55 °C 

  • Allowable relative humidity range: 5% – 95% (non-condensing) 

  • Max operating altitude: ≤ 2000 m

  • Cooling method: Smart forced air cooling 

  • Noise (typical): ≤50 dB(A) 

  • EMC: Class B 

Certification and Standards

  • Certifications: CE, CB, UKCA, RCM, ADQCC, MOIAT, PEA, SASO, MEW

  • Compliance: ETSI/EN 300 328, EN 300 330, EN 301 489-1/3/17/52, ETSI/EN 301 908-1/13, EN 50665, BS/EN IEC 61851-1, BS/EN IEC 61851-21-2, BS/IEC EN 61851-23/24, EN IEC 62311

  • Warranty: 3 years (standard)Â